Solar Sensors
Solar Irradiation Sensors
![Solar Irradiation Sensor](https://suryalogix.com/wp-content/uploads/2023/04/Solar-Irradiation-Sensor.webp)
• Used to measure Solar Radiation flux density
• Available in both Analog and Digital output.
• Housing / Enclosure: UV-resistant PVC plastic
• Ingress Protection (IP): IP65 with both plugs securely attached.
• Reading helps in calculating the Performance Ratio of the plant
Specifications & Features
![Ethernet](https://suryalogix.com/wp-content/uploads/2021/10/Ethernet.png)
Output:
RS-485 Based
![Accuracy-Surya](https://suryalogix.com/wp-content/uploads/2021/10/Accuracy-Surya-1.png)
Accuracy:
Up to ±2.5%
![Supply-Voltage](https://suryalogix.com/wp-content/uploads/2021/10/Supply-Voltage.png)
Supply Voltage:
12 to 28Vdc
![Measuring-Range](https://suryalogix.com/wp-content/uploads/2021/10/Measuring-Range-1.png)
Measuring Range:
0 to 1600 W/m²
Ambient Temperature Sensor
![Ambient-Temperature-Sensor](https://suryalogix.com/wp-content/uploads/2023/04/Ambient-Temperature-Sensor.webp)
• Used to measure the surrounding temperature
• Housing / Enclosure: PolyCarbonate Watertight enclosure
• Sensor Type: Pt100Ω Class A IEC 60751
• Easily configurable with SCADA and Data logger
• Both Digital and Analog output are available
Specifications & Features
![Accuracy-Surya](https://suryalogix.com/wp-content/uploads/2021/10/Accuracy-Surya-1.png)
Accuracy:
Up to ±0.3°C
![Supply-Voltage](https://suryalogix.com/wp-content/uploads/2021/10/Supply-Voltage.png)
Supply Voltage:
12 to 28VDC
![IP-65](https://suryalogix.com/wp-content/uploads/2021/10/IP-65-1.png)
Ingress Protection (IP): IP-65
![Measuring-Range](https://suryalogix.com/wp-content/uploads/2021/10/Measuring-Range-1.png)
Measuring Range:
0 to 100°C
Module Temperature Sensor
![Module-Tempreauture-sensor](https://suryalogix.com/wp-content/uploads/2023/04/Module-Tempreauture-sensor.webp)
- Specifically used to Measure Module Temperature Sensor
- Output available in both Analog and Digital
- Reading helps in Calculating the Performance Ratio of the Plant
Specifications & Features
![IP-65](https://suryalogix.com/wp-content/uploads/2021/10/IP-65-1.png)
Ingress Protection (IP): IP-65
![Measuring-Range](https://suryalogix.com/wp-content/uploads/2021/10/Measuring-Range-1.png)
Measuring Range:
0 to 100°C
![Accuracy-Surya](https://suryalogix.com/wp-content/uploads/2021/10/Accuracy-Surya-1.png)
Accuracy:
Up to ±0.3°C
![Supply-Voltage](https://suryalogix.com/wp-content/uploads/2021/10/Supply-Voltage.png)
Supply Voltage:
12 to 28VDC
Wind Speed & Direction Sensor
![Wind-Speed-Direction-Sensor-nobg](https://suryalogix.com/wp-content/uploads/2023/04/Wind-Speed-Direction-Sensor-nobg.webp)
- Used to Measure Wind Speed & Direction
- Anemometer includes both Wind Speed and Wind Direction Sensors
- Cup & Vane type Measuring Device
- Provides a critical parameter to consider from the Plant Safety Perspective
- Polycarbonate Material (Default) or Metal (Optional) is used for Wind Cups & Vanes
Specifications & Features
![Wind Speed](https://suryalogix.com/wp-content/uploads/2023/03/Wind-Speed.png)
Wind Speed:
0 to 69.44 m/s
![Wind Direction](https://suryalogix.com/wp-content/uploads/2023/03/Wind-Direction.png)
Wind Direction:
0 to 360 degrees
![Supply-Voltage](https://suryalogix.com/wp-content/uploads/2021/10/Supply-Voltage.png)
Supply Voltage:
12 - 24 VDC
![Analog+Digital](https://suryalogix.com/wp-content/uploads/2023/03/AnalogDigital.png)
Output:
Digital & Analog
Ambient Temperature & Humidity Sensor
![Ambient-Humidity](https://suryalogix.com/wp-content/uploads/2023/04/Ambient-Humidity.webp)
- Used to measure and monitor the amount of Moisture in the surrounding Atmosphere
- Sensors include Temperature and Humidity Sensors with the Shield.
- Provides the Actual Humidity Condition with Ambient Temperature
- Humidity (0 – 100 % RH)
- Ambient Temperature (-40 – 120 °C)
- Digital and Analog outputs are available
Specifications & Features
![Humidity](https://suryalogix.com/wp-content/uploads/2023/03/Humidity.png)
Humidity Sensor:
0 - 100 % RH
![Supply-Voltage](https://suryalogix.com/wp-content/uploads/2021/10/Supply-Voltage.png)
Supply Voltage:
12 to 28VDC
![IP-65](https://suryalogix.com/wp-content/uploads/2021/10/IP-65-1.png)
Ingress Protection (IP): IP-65
![Measuring-Range](https://suryalogix.com/wp-content/uploads/2021/10/Measuring-Range-1.png)
Ambient Temp Range:
40 - 120 °C
Pyranometer
![Pyranometer](https://suryalogix.com/wp-content/uploads/2023/04/Pyranometer.webp)
- Used to Measure Independent, Accurate Readings of the Total available Solar Radiation
- Digital and Analog outputs are available
- Faster responsivity
- Monitor the wide Solar Spectrum with Increased Accuracy
Specifications & Features
![Irradiation](https://suryalogix.com/wp-content/uploads/2023/03/Irradiation.png)
Irradiation Range:
0 - 2000W/m²
![](https://suryalogix.com/wp-content/uploads/2023/03/C.png)
Class: Equivalent to class “C”
![Accuracy-Surya](https://suryalogix.com/wp-content/uploads/2021/10/Accuracy-Surya-1.png)
Sensitivity:
50 to 100 µV/W/m²
![](https://suryalogix.com/wp-content/uploads/2023/03/Photodiode.png)